Review



microguidewire synchro select soft pre-shaped  (Stryker)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Stryker microguidewire synchro select soft pre-shaped
    Microguidewire Synchro Select Soft Pre Shaped, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/synchro+14+microguidewire/pmc12035768-94-16-21
    Average 90 stars, based on 1 article reviews
    microguidewire synchro select soft pre-shaped - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Infectious intracranial aneurysm caused by infective endocarditis following buccal fat pad removal – An esthetic plastic procedure
    Article Snippet: A Rist 6-French radial access guide catheter (Medtronic; Dublin, Ireland) was placed in the right ascending petrous segment of the internal carotid artery, and a Phenom 17 microcatheter (Medtronic; Dublin, Ireland), supported by a 3.4-French Guidepost intermediate catheter (Tokai Medical, Aichi, Japan) was navigated into the M1 aneurysm using a Synchro SELECT soft microguidewire (Stryker; Kalamazoo, MI, USA).



    Similar Products

    90
    Stryker microguidewire synchro select soft pre-shaped
    Microguidewire Synchro Select Soft Pre Shaped, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/synchro+14+microguidewire/pmc12035768-94-16-21
    Average 90 stars, based on 1 article reviews
    microguidewire synchro select soft pre-shaped - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    86
    Stryker synchro select soft microguidewire
    Synchro Select Soft Microguidewire, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/select+soft+synchro+%E2%80%A2/pmc12477961-32-50-54
    Average 86 stars, based on 1 article reviews
    synchro select soft microguidewire - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    90
    Stryker microguidewire synchro select soft
    Microguidewire Synchro Select Soft, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/synchro+14+microguidewire/pmc11779502-86-21-25
    Average 90 stars, based on 1 article reviews
    microguidewire synchro select soft - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Stryker microguidewire synchro select guidewire soft
    Intraoperative DSA during TVE. ( A ) The lateral view shows the microcatheter inserted into the left sigmoid sinus through the tortuous confluence (white arrowhead). ( B ) The lateral view shows a partially packed left sigmoid sinus with several coils. ( C ) Frontal view shows the fractured <t>microguidewire</t> (black arrowhead). TVE, transvenous embolization
    Microguidewire Synchro Select Guidewire Soft, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/microguidewire+synchro+standard/pmc11491270-26-12-17
    Average 90 stars, based on 1 article reviews
    microguidewire synchro select guidewire soft - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Stryker microguidewire synchro select soft 0.014 inch
    Intraoperative DSA image showing the <t>microguidewire</t> being entangled with the stent and stuck.
    Microguidewire Synchro Select Soft 0.014 Inch, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/synchro+select+soft+microguidewire/microguidewire+synchro+standard/pmc10730298-23-23-29
    Average 90 stars, based on 1 article reviews
    microguidewire synchro select soft 0.014 inch - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    Intraoperative DSA during TVE. ( A ) The lateral view shows the microcatheter inserted into the left sigmoid sinus through the tortuous confluence (white arrowhead). ( B ) The lateral view shows a partially packed left sigmoid sinus with several coils. ( C ) Frontal view shows the fractured microguidewire (black arrowhead). TVE, transvenous embolization

    Journal: JNET Journal of Neuroendovascular Therapy

    Article Title: Subarachnoid Hemorrhage of Unknown Cause after Transvenous Embolization of Transverse Sigmoid Sinus Dural Arteriovenous Fistula Followed by Transarterial Embolization: A Case Report

    doi: 10.5797/jnet.cr.2024-0030

    Figure Lengend Snippet: Intraoperative DSA during TVE. ( A ) The lateral view shows the microcatheter inserted into the left sigmoid sinus through the tortuous confluence (white arrowhead). ( B ) The lateral view shows a partially packed left sigmoid sinus with several coils. ( C ) Frontal view shows the fractured microguidewire (black arrowhead). TVE, transvenous embolization

    Article Snippet: However, attempts to reposition the microcatheter led to a fracture of the microguidewire (Synchro SELECT Guidewire Soft; Stryker, Portage, MI, USA), resulting in a 10-cm long piece of broken wire left behind in the transverse sinus.

    Techniques:

    ( A–D ) Intraoperative DSA via microcatheter during TAE, frontal view ( A and C ), and lateral view ( B and D ). Microcatheter is inserted via the petrosquamous branch of the middle meningeal artery into the left transverse sinus through the shunt point ( A and B , black arrowhead). Sphenopetrosal vein ( A and B , black arrow). Microguidewire remnant after fracture ( A and B , white arrowhead). Onyx cast front end ( C and D , black arrow). ( E ) Illustration of the treatment progress. A: left transverse sinus, B: left sigmoid sinus, black arrow: approach direction during TVE, dotted line arrow: approach direction during TVE. CVR, cortical venous reflux; OA, occipital artery; PA, posterior auricular artery; TAE, transarterial embolization; TVE, transvenous embolization

    Journal: JNET Journal of Neuroendovascular Therapy

    Article Title: Subarachnoid Hemorrhage of Unknown Cause after Transvenous Embolization of Transverse Sigmoid Sinus Dural Arteriovenous Fistula Followed by Transarterial Embolization: A Case Report

    doi: 10.5797/jnet.cr.2024-0030

    Figure Lengend Snippet: ( A–D ) Intraoperative DSA via microcatheter during TAE, frontal view ( A and C ), and lateral view ( B and D ). Microcatheter is inserted via the petrosquamous branch of the middle meningeal artery into the left transverse sinus through the shunt point ( A and B , black arrowhead). Sphenopetrosal vein ( A and B , black arrow). Microguidewire remnant after fracture ( A and B , white arrowhead). Onyx cast front end ( C and D , black arrow). ( E ) Illustration of the treatment progress. A: left transverse sinus, B: left sigmoid sinus, black arrow: approach direction during TVE, dotted line arrow: approach direction during TVE. CVR, cortical venous reflux; OA, occipital artery; PA, posterior auricular artery; TAE, transarterial embolization; TVE, transvenous embolization

    Article Snippet: However, attempts to reposition the microcatheter led to a fracture of the microguidewire (Synchro SELECT Guidewire Soft; Stryker, Portage, MI, USA), resulting in a 10-cm long piece of broken wire left behind in the transverse sinus.

    Techniques: Reflux

    Intraoperative DSA image showing the microguidewire being entangled with the stent and stuck.

    Journal: JNET Journal of Neuroendovascular Therapy

    Article Title: A Case of Microguidewire and Neuroform Atlas Stent Entanglement Resulting in Extraction Difficulty

    doi: 10.5797/jnet.cr.2023-0055

    Figure Lengend Snippet: Intraoperative DSA image showing the microguidewire being entangled with the stent and stuck.

    Article Snippet: We used a combination of a distal access catheter (Tactics; Technocrat Corporation, Aichi, Japan), microcatheter (Headway 17; Terumo Medical Corporation, Tokyo, Japan), and microguidewire (Synchro SELECT Soft 0.014 inch; Stryker, Fremont, CA, USA).

    Techniques:

    Intraoperative DSA image. ( A ) Image of a 2-mm gooseneck snare (white arrow) being guided along a tangled microguidewire (black arrow). ( B ) Image of a microguidewire (black arrow) being pulled by a gooseneck snare and a stent (white arrow) in the process of sliding down. ( C ) A stent (black arrows) that has slipped down and a newly placed stent (white arrows).

    Journal: JNET Journal of Neuroendovascular Therapy

    Article Title: A Case of Microguidewire and Neuroform Atlas Stent Entanglement Resulting in Extraction Difficulty

    doi: 10.5797/jnet.cr.2023-0055

    Figure Lengend Snippet: Intraoperative DSA image. ( A ) Image of a 2-mm gooseneck snare (white arrow) being guided along a tangled microguidewire (black arrow). ( B ) Image of a microguidewire (black arrow) being pulled by a gooseneck snare and a stent (white arrow) in the process of sliding down. ( C ) A stent (black arrows) that has slipped down and a newly placed stent (white arrows).

    Article Snippet: We used a combination of a distal access catheter (Tactics; Technocrat Corporation, Aichi, Japan), microcatheter (Headway 17; Terumo Medical Corporation, Tokyo, Japan), and microguidewire (Synchro SELECT Soft 0.014 inch; Stryker, Fremont, CA, USA).

    Techniques:

    Image of the experiment. The stent was implanted into a clear artificial vessel, and a combination of SL-10 and microguidewire was used to guide the wire into the stent. This system was used to examine whether the stent and microguidewire will entangle.

    Journal: JNET Journal of Neuroendovascular Therapy

    Article Title: A Case of Microguidewire and Neuroform Atlas Stent Entanglement Resulting in Extraction Difficulty

    doi: 10.5797/jnet.cr.2023-0055

    Figure Lengend Snippet: Image of the experiment. The stent was implanted into a clear artificial vessel, and a combination of SL-10 and microguidewire was used to guide the wire into the stent. This system was used to examine whether the stent and microguidewire will entangle.

    Article Snippet: We used a combination of a distal access catheter (Tactics; Technocrat Corporation, Aichi, Japan), microcatheter (Headway 17; Terumo Medical Corporation, Tokyo, Japan), and microguidewire (Synchro SELECT Soft 0.014 inch; Stryker, Fremont, CA, USA).

    Techniques: